Thermocouple Connector Systems (Two Pole)

Connector || Jab In Style Connector || Accessories || Miniature Connector
High Temp. Connector || High Temp. Jab In Style Connector || High Temp. Accessories
Jack Panel FS Box || Snap-in Panel Jack || Single Circuit Jack Panel
2 Pole Multicircuit Jack Panel || Terminal Boxes & Strips


Thermocouple Terminal Boxes

d8a

  • Weatherproof sheet steel multi-circuit box protects thermocouple and instrument cables from corrosive or dirty environments.
  • Rigid weatherproof junction box which meets JIC specifications in dash 1, 2, 3 and 4 models and NEMA specifications in the dash 5, 6, 7 and 8 models. Heavy, 14 to 16 gauge sheet steel, welded seams and neoprene gasketed covers provide a strong rigid weatherproof box.
  • Boxes have removable platform type terminal strip panels, lugs for wall mounting and quick and easy screw clamps.
  • Boxes are finished in a baked gray hammertone enamel.
  • Entrance hubs are affixed to the box wall to provide effective resistance to moisture.
  • These boxes are also available in cast aluminum or cast iron constructions on special order.

Terminal Strip Arrangement

d8b

All boxes 6" deep except 104-1 is 4" and 104-2 is 5". External dimensions shown.

Part No. Number of
Contacts
Max T/C
Circuits
Cable Pairs
Accepted
Cable Wire
Size (AWG)
104-1 12 6 4 or 6 16, 20
104-2 28 14 8 or 12 16, 20
104-3 36 18 16 20
104-4 52 26 20 or 24 20
104-5 80 40 39 20
104-6 112 56 56 20
104-7 156 78 -- --
104-8 208 104 -- --



Terminal Strips

Terminal strips used in these boxes are manufactured of phenolic material and will withstand temperatures from -40°F to +250°F. All terminals are nickel-plated brass. Strips are screwed directly to the box floor on cast iron models, while sheet steel boxes have the strips screwed to removable panels. All terminals are numerically identified.

Ordering Information: Specify #1044BR__. Insert the number of terminals desired in the blank. For terminals of Thermocouple material, specify calibration in place of BR.

d8c


Terminal Lugs

Ordering Information: Specify #1044TL Insert Thermocouple calibration desired. Each lug has stamped-in designation of thermocouple material:
  • IR - iron
  • CO - constantan
  • CU - undesignated
d8d

 